Feature
- Soft-start current can reduce the AC input impact effectively
- With short-circuit and overload protection
- 100% full-load burn-in test
- Installed with EMI filter, minimum wave
Specification
Model | S-15-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 0.625A | |
CURRENT RANGE | 0 ~ 0.625A | |
RATED POWER | 15W | |
RIPPLE&NOISE(Max) | 100mVp-p | |
VOLTAGE ADJ.RANGE | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP,RISE TIME | 200ms, 100ms | |
HOLD UP TIME(Typ.) | 30ms (full load) | |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120~370VDC |
FREQUENCY RANGE | 47~63Hz | |
EFFICIENCY(Typ.) | 0.82 | |
AC CURRENT(Typ.) | 0.25A/230V | |
INRUSH CURRENT(Typ.) | COLD START 65A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVER LOAD |
115 ~ 135% rated output power |
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||
OVER VOLTAGE |
28.4 ~ 32.4V | |
Protection type : Shut off o/p voltage, clamping by zener diode | ||
ENVIRONMENT | WORKING TEMP | -10 ~ +60°C (Referto derating curve ) |
WORKING HUMIDITY | 20~90%RH non-condensing | |
STORAGETEMP.,HUMIDITY | -20 ~ +85°C, 20 ~ 95% RH | |
TEMP.COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min/1cycle,60min.eachX、Y、Zaxes | |
SAFETY | SAFETY STANDARDS | GB4943.1, EN60950.1APPROVED |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100MOhms/500VDC | |
EMC EMISSION | Compliance toEN61000-3-2:2014/EN61000-3-3:2013 | |
EMC IMMUNITY | Compliance toEN55032:2015/EN55035:2017/60950-1 | |
OTHERS | MTBF | ≥763.6K hrs MIL-HDBK-217F(25°C) |
DIMENSION | 99*97*35mm (L*W*H) |