Safeguard Your AC System with Schneider Electric VIGILOHM IM9>
The Schneider Electric VIGILOHM IM9 is your proactive partner in preventing electrical faults in small, clean AC systems. This innovative insulation monitoring device (IMD) acts as an early warning system, constantly assessing your system’s health and preventing costly downtime.
Feature of Schneider IMD IM9
- Early Fault Detection: Continuously monitors insulation resistance, identifying potential problems before they escalate into costly breakdowns.
- Reduced Downtime: Receive alerts for potential ground faults, allowing you to address issues proactively and minimize disruptions.
- Enhanced Safety: Proactive fault detection minimizes the risk of electrical accidents and equipment damage.
- Customizable Protection: Set pre-alarm and alarm thresholds to tailor the IMD to your specific needs.
- Easy Installation: Compact and user-friendly design simplifies installation and integration into your existing system.
- Injection of a DC measuring signal
- Power supply: 110…415 VAC, or 125…250 VDC
- 1 settable alarm and 1 settable pre-alarm threshold
- 1 NO-NC alarm relay
- Local and remote self-test
Specification of Schneider Electric VIGILOHM IM9
Specification | Parameters |
AC (max phase to phase voltage) | 480 VAC, 600VAC |
DC (max line voltage) | Not compatible |
Frequency | Purely AC networks |
Grounding arrangement | IT / ungrounded/Earthing system |
Power supply | 118-415 VAC / 125-250 VDC |
Insulation resistance | Accuracy at 10 kΩ, 1 µF <15% |
Fault signaling threshold | Preventive alarm: 2; 5; 10; 20; 50: 100; 200; 500 kΩ Alarm: 1; 2,5; 5; 10; 25; 50; 100; 250 kΩ |
Test function | Remote test Local |
Power consumption in VA | 7 VA |
Measurement current | 0…70 µA |
internal impedance | 230 kOhm – AC at 45…440 Hz |
Response time | ≤ 2 s |
output contact | 1 C/O standard or fail-safe |
Breaking capacity | 250 V – AC at 6 A |
12…24 V – DC at 6 A | |
IP degree of protection | Case: IP20 |
Front face: IP40 | |
Environmental characteristic | Exposure to damp heat not in service conforming to IEC 60068-2-30 |
Exposure to damp heat in service conforming to IEC 60068-2-56 | |
Salt mist conforming to IEC 60068-2-52 | |
Type of installation | Indoor |
Standards | IEC 61557-8 |
IEC 60664-1 | |
Product certifications | EAC |
CE | |
BV | |
RMRS | |
DNV | |
Ambient air temperature for operation | -25…55 °C |
ambient air temperature for storage | -40…70 °C |
Application of Schneider VIGILOHM IM9
- Pure AC networks with no DC component.
- Network of limited dimension (<5km of cable) with no disturbance loads.