SDR-240 Series Industrial Switching Power Supply 240W Single Output DIN RAIL with PFC Function

Contact us

Feature

  • High efficiency 94% and low power dissipation
  • 150% peak load capability
  • Built-in active PFC function, PF>0.93
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL 508 (industrial control equipment} approved
  • BS EN/EN61000-6-2(BS EN/EN50082-2} industrial immunity level
  • Built-in DC OK relay contact
  • 100% full load burn-in test

 

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

 

MODEL SDR-240-24 SDR-240-48
 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 24V 48V
RATED CURRENT 10A 5A
CURRENT RANGE 0 ~ 10A 0 ~ 5A
RATED POWER 240W 240W
PEAK CURRENT 15A 7.5A
PEAK POWER Note.6 360W (3sec.)
RIPPLE & NOISE (max.) Note.2 50mVp-p 50mVp-p
VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0%
SETUP, RISE TIME 650ms, 60ms/230VAC          1300ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.) 20ms/230VAC           20ms/115VAC at full load
 

 

 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC           124 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) 0.94/230VAC           0.99/115VAC at full load
EFFICIENCY (Typ.)                                                Note.8 94%
AC CURRENT (Typ.) 2.6A/115VAC           1.3A/230VAC
INRUSH CURRENT (Typ.) 33A/115VAC           55A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
 

 

 

 

PROTECTION

 

OVERLOAD

Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery
>150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds
 

OVER VOLTAGE

29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery
 

OVER TEMPERATURE

95℃±5℃ (TSW : detect on heatsink of power switch)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
 

 

 

ENVIRONMENT

WORKING TEMP.                                                Note.5 -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
 

 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved;(meet BS EN/EN60204-1)
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
 

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2),

BS EN/EN61204-3, heavy industry level, EAC TP TC 020, SEMI F47 approved

 

OTHERS

MTBF 1160.3K hrs min.       Telcordia SR-332 (Bellcore) ; 169.3K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 63*125.2*113.5mm (W*H*D)
PACKING 1.03Kg; 12pcs/13.4Kg/1.22CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.

6. 3 seconds max., please refer to peak loading curves.

7. Derating may be needed under low input voltage. Please check the derating curve for more details.

8. After 30 minutes of burn-in.

9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.