EDR-120 series 120W Single Output Industrial DIN RAIL

Contact us

Feature

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • / Over temperature
  • Cooling by free air convection
  • Can be installed on DlN rail TS-35/7.5 or 15
  • UL 508 (industrial control equipment} approved
  • BS EN/EN61000-6-2(BS EN/EN50082-2} industrial immunity level
  • 100% full load burn-in test
  • 2 years warranty

 

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

 

MODEL EDR-120-12 EDR-120-24 EDR-120-48
 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 12V 24V 48V
RATED CURRENT 10A 5A 2.5A
CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A
RATED POWER 120W 120W 120W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 12 ~ 14V 24 ~ 28V 48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 1200ms, 60ms/230VAC        2500ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC         10ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE        Note.6 90 ~ 264VAC       127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85% 87.5% 88.5%
AC CURRENT (Typ.) 2.25A/115VAC        1.3A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC        35A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
 

 

 

PROTECTION

 

OVERLOAD

105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
 

OVER VOLTAGE

14 ~ 17V 29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
 

 

 

ENVIRONMENT

WORKING TEMP. -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL508,TUV BS EN/EN62368-1,EAC TP TC 004,BSMI CNS14336-1,IS13252(Part1)/IEC60950-1 approved;(meet BS EN/EN60204-1)
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class A, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class A
 

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2),

heavy industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF 2718.3K hrs min.      Telcordia SR-332 (Bellcore) ; 474.7K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 40*125.2*113.5mm (W*H*D)
PACKING 0.6Kg; 20pcs/13Kg/1.16CUFT
 

 

 

 

 

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5.  lnstallation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended.

6.  Derating may be needed under low input voltage. Please check the derating curve for more details.

7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.