Feature
- AC input active surge current limiting
- AC input range selected by switch
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC ball bearing fan
- High power density 7.3w/inch3
- With DC_OK signal output
- Built-in remote ON-OFF control
- Built-in remote sense function
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment
- or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- DC centralized bus(Lighting)
Specification
MODEL | SE-1000-5 | SE-1000-9 | SE-1000-12 | SE-1000-15 | SE-1000-24 | SE-1000-48 | |
OUTPUT |
DC VOLTAGE | 5V | 9V | 12V | 15V | 24V | 48V |
RATED CURRENT | 150A | 100A | 83.3A | 66.7A | 41.7A | 20.8A | |
CURRENT RANGE | 0 ~ 150A | 0 ~ 100A | 0 ~ 83.3A | 0 ~ 66.7A | 0 ~ 41.7A | 0 ~ 20.8A | |
RATED POWER | 750W | 900W | 999.6W | 1000.5W | 1000.8W | 998.4W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.3 ~ 5.5V | 7.5 ~ 10V | 10 ~ 13.5V | 13.5 ~ 16.5V | 22 ~ 27.5V | 43 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 20ms/230VAC 15ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC selected by TB2 254 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 81% | 84% | 85% | 86% | 88% | 89% | |
AC CURRENT (Typ.) | 17.5A/115VAC 10A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 55A/230VAC | ||||||
LEAKAGE CURRENT | <2.5mA / 240VAC | ||||||
PROTECTION |
OVERLOAD |
105 ~ 125% rated output power | |||||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER VOLTAGE |
5.75 ~ 6.75V | 10.4 ~ 12.2V | 13.8 ~ 16.2V | 18 ~ 21V | 28 ~ 32.4V | 57.6 ~ 67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
FUNCTION |
DC_OK SIGNAL | PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V | |||||
REMOTE CONTROL | RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off | ||||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +60℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, BSMI CNS14336-1, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1 | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 (CISPR32) | Class A | |||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | |||||
Harmonic Current | BS EN/EN61000-3-2 | —– | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2 | ||||||
Parameter | Standard | Test Level / Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | |||||
Surge | BS EN/EN61000-6-2 | 1KV/Line-Line 2KV/Line-Earth | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 1273.6K hrs min. Telcordia SR-332 (Bellcore) ; 251.6K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 278*127*63.5mm (L*W*H) | ||||||
PACKING | 2.5Kg; 6pcs/16Kg/1.38CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 5. By using UVP circuit, PSU will not turn on direct by in AC continue ON/OFF condition within 5 sec. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. 7. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions: a} the end-devices is used within the European Union, and b} the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c} the power supply is: – installed in end-devices with average or continuous input power greater than 75W, or – belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 a} professional equipment with a total rated input power greater than 1000W; b} symmetrically controlled heating elements with a rated power less than or equal to 200W
|