Feature
- The modular design of the product range allows a number of versions with a smaller number of bearing types for enclosures and operating mechanisms.
- All operating mechanisms can be rotated around the axis in increments of 22.5° (see Overview → Mounting).
- Rounded and roller plungers according to EN 50041 with 3 mm overtravel (total travel 9 mm) for greater tolerance when switching.
- All enclosure sizes – now also including the small enclosure 31-mm wide – are optionally available with an LED signaling indicator (see Overview → Optional LED indicators).
- All enclosure variants have an integrated chlorinated rubber diaphragm for high functional safety in cold and aggressive environments.
- All contact blocks are replaceable (see Accessories and spare parts).
- The 3-pole contact blocks are available for all enclosure sizes (see Overview → Diverse contact types).
- Elements with 1 NO + 2 NC slow-action contacts with make-before-break and 2 NO + 1 NC
- The short-stroke contact block 1 NO + 1 NC improves the precision of the switching operation through a reduced actuation path.
- The contact block with 1 NO + 1 NC snap-action contacts with a contact distance of 2 x 2 mm is suitable for simultaneous shutdown and signaling, particularly in the elevator industry.
- XL metal enclosures for accommodating two 2- or 3-pole contact blocks
- Versions with plugs for safe and fast connection, e.g. to fail-safe field modules of SIMATIC ET 200eco PN or SIMATIC ET 200AL
- The plastic enclosures with a width of 31 mm have simple and fast wiring equipment, making it possible to achieve time savings of approx. 20 to 25% when connecting (see Overview → Quick-connect technology).
- The ASIsafe electronics are integrated in the enclosure for the versions with AS‑Interface connection (see SIRIUS 3SF1 mechanical safety switches for AS-Interface); an additional adapter is not required.
Specification
Type |
|
3SE51..1), 3SE52..1) |
3SE541. |
3SE542. |
---|---|---|---|---|
Standards |
|
IEC 60947-5-1, ISO 14119 |
||
Rated insulation voltage U i |
V |
4002) |
400 |
|
Pollution degree according to IEC 60664‑1 |
|
Class 3 |
Class 3 |
|
Rated impulse withstand voltage U imp |
kV |
6 |
4 |
|
Rated operational voltage U e |
V |
400 AC; over 300 V AC same potential only3) |
AC 300 |
|
Conventional thermal current I th |
A |
10 |
10 |
|
Rated operational current I e |
|
|
||
|
|
I e/AC-15 |
I e/AC-15 |
|
|
A |
6 |
6 |
|
|
A |
6 |
6 |
|
|
A |
6 |
3 |
|
|
A |
4 |
— |
|
|
|
I e/DC-13 |
I e/DC-13 |
|
|
A |
3 |
3 |
|
|
A |
0.55 |
0.55 |
|
|
A |
0.27 |
0.27 |
|
|
A |
0.12 |
— |
|
Short-circuit protection 4) |
|
|
||
|
A |
6 |
10 |
|
|
A |
1 |
3 |
|
Mechanical endurance |
|
|
||
|
|
15 × 106 operating cycles |
10 × 106 operating cycles |
10 × 106 operating cycles |
|
|
10 × 106 operating cycles |
— |
— |
|
|
1 × 106 operating cycles |
— |
— |
Electrical endurance |
|
|
||
|
|
10 × 106 operating cycles |
500 000 operating cycles |
500 000 operating cycles |
|
|
100 000 operating cycles |
100 000 operating cycles |
100 000 operating cycles |
|
|
For direct current depending on the loading of the switch |
||
Switching frequency |
|
|
||
With 3RH21 contactors size S00 and 3RT2 contactors sizes S00, S0 |
|
6 000 operating cycles/h |
1 800 operating cycles/h |
|
Switching accuracy |
|
|
||
|
mm |
0.05 |
0.05 |
|
|
|
1° |
1° |
|
Rated data according to CSA, UL and UR |
|
|
||
|
V |
300 |
300 |
|
|
A |
6 |
10 |
|
|
|
Heavy duty, A 300/B 300/Q 300 |
A 300/Q 300 |