Feature
-
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
-
High degree of insert compatibility and design as per DIN 43772
-
Extension neck to protect the head transmitter from overheating
-
Fast response time with reduced/tapered tip form
-
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA)
-
Head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
-
Universal range of application
-
Particularly suitable for steam and gas applications with high process pressures and temperatures
-
Measuring range: –40 to 1100 °C (–40 to 2012 °F)
-
Static pressure range up to 400 bar (5800 psi)
-
Degree of protection: up to IP68
Specification
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
-
Max. process pressure (static)
at 20 °C: 400 bar (5.802 psi)
-
Operating temperature range
Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 750 °C
(max. 1.382 °F) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10”)