Feature
- 
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths 
- 
High degree of insert compatibility and design as per DIN 43772 
- 
Extension neck to protect the head transmitter from overheating 
- 
Fast response time with reduced/tapered tip form 
- 
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA) 
- 
Head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™ 
- 
Universal range of application 
- 
Particularly suitable for steam and gas applications with high process pressures and temperatures 
- 
Measuring range: –40 to 1100 °C (–40 to 2012 °F) 
- 
Static pressure range up to 400 bar (5800 psi) 
- 
Degree of protection: up to IP68 
Specification
- 
Accuracyclass 1 acc. to IEC 60584 
- 
Response timedepending on configuration 
- 
Max. process pressure (static)at 20 °C: 400 bar (5.802 psi) 
- 
Operating temperature rangeType K: 
 max. 1.100 °C
 (max. 2.012 °F)
 Type J:
 max. 750 °C
 (max. 1.382 °F)
- 
Max. immersion length on requestup to 30.000,00 mm (1.181,10”) 
 
								



