Standard
UL Subject 758&UL1581/CSA C22.2 NO.210.05
Stranded, tinned, or bare copper conductor Lead-free PVC insulation
Passed UL VW-1 vertical test
Application
For internal wiring of electronic and electrical equipment. Can be substituted by UL21311&UL21458
Specification
Part-No |
Cores |
Conductor |
Insulation thickness |
Insulation diameter |
Shield |
Jacket thickness |
Jacket diameter |
Conductor resistance at20℃
Max |
|
AWG | NO./mm | mm | mm | mm | mm | mm | Ω/km | ||
EKF50802 | 2 | 30 | 7/0.102 | 0.25 | 0.80 | 45/0.10 | 0.50 | 2.70 | 381 |
EKF50802 | 4 | 30 | 7/0.102 | 0.25 | 0.80 | 58/0.10 | 0.39 | 2.90 | 381 |
EKF50802 | 8 | 30 | 7/0.102 | 0.13 | 0.55 | 58/0.10 | 0.70 | 3.50 | 381 |
EKF50802 | 2 | 28 | 19/0.08 | 0.15 | 0.70 | — | 0.40 | 2.20 | 239 |
EKF50802 | 11 | 28 | 7/0.127 | 0.22 | 0.82 | 16/5/0.12 | 0.60 | 5.20 | 239 |
EKF50802 | 11 | 28 | 7/0.127 | 0.14 | 0.65 | 16/5/0.12 | 0.38 | 3.70 | 239 |
EKF50802 | 13 | 28 | 7/0.127 | 0.14 | 0.65 | 16/5/0.12 | 0.53 | 4.50 | 239 |
EKF50802 | 4 | 26 | 7/0.160 | 0.26 | 1.00 | 16/5/0.12 | 0.87 | 5.00 | 150 |
EKF50802 | 2 | 24 | 11/0.16 | 0.25 | 1.10 | 55/0.12 | 0.53 | 3.50 | 94.2 |
EKF50802 | 2 | 24 | 45/0.08 | 0.25 | 1.10 | 16/5/0.12 | 0.86 | 4.50 | 94.2 |
EKF50802 | 2 | 24 | 19/0.12 | 0.20 | 1.00 | — | 0.37 | 2.75 | 94.2 |
EKF50802 | 4 | 22 | 17/0.16 | 0.25 | 1.30 | 70/0.12 | 0.58 | 4.50 | 59.4 |