Features
- Real-time monitoring of power quality parameters
- Reports and charts can be provided
- Improve the reliability and stability of the power grid
- Power quality analysis, diagnosis of grid quality
- Remote monitoring, real time monitor power quality
- Failure early warning, detection of potential equipment failures
- Can record historical data to facilitate analysis and prediction of power quality change trends
- Automatic alarm, automatically send an alarm signal when the power quality is abnormal
- Optimize grid operation, reduce energy consumption, and improve grid efficiency
Application
- Energy Metering and Billing
- Smart grid construction and operation
- Power system operation monitoring and analysis
- Industrial production equipment power quality monitoring and analysis
- Power quality improvement program design and implementation
- Power system installation and operation inspection
- Construction and operation monitoring of renewable energy power stations
- power quality monitoring and management
Specification
| Parameter | Value |
| Frequency | 40-70Hz / 0.01Hz / ±0.03Hz |
| True RMS Voltage | 1.0-1000V / 0.1 / ±(0.5%+5dgt) |
| True RMS Line Voltage | 1.0-2000V / 0.1 / ±(0.5%+5dgt) |
| DC Voltage | 1.0-1000V / 0.1 / ±(1.0%+5dgt) |
| True RMS Current | 10mA-9000A / 1mA / ±(0.5%+5dgt) |
| Phase Voltage Peak | 1.0-1414V / 0.1 / ±(1.0%+5dgt) |
| Neutral Line voltage Peak | 1.0-2828V / 0.1 / ±(1.0%+5dgt) |
| Current Peak | 10mA-12727A / 1mA / ±(1.0%+5dgt) |
| CF | 1.0~3.99 / 0.01 / ±(1%+2dgt) 4~9.99 / 0.01 / ±(5%+2dgt) |
| Active Power | 0.000W-9000.0kW / 0.001W / ±(1%+3dgt)@PF>0.8 0.000W-9000.0kW / 0.001W / ±(1.5%+10dgt)@0.2<PF<0.8 |
| Reactive Power, inductive or capacitive |
0.000Var-9000.0kVar / 0.001Var / ±(1%+3dgt)@PF<-0.5 0.000Var-9000.0kVar / 0.001Var / ±(1.5%+10dgt)@-0.5<PF<-0.2 |
| Apparent Power | 0.000VA-9000.0kVA / 0.001VA / ±(1%+3dgt) |
| Power Factor | -1.000~1.000 / 0.001 / ±(1.5%+3dgt)@PF>0.5 -1.000~1.000 / 0.001 / ±(1.5%+10dgt)@0.2<PF<0.5 |
| Active Electrical Energy | 0.000Wh-9000.0MWh / 0.001Wh / ±(1%+3dgt)@PF>0.8 0.000Wh-9000.0MWh / 0.001Wh / ±(1.5%+10dgt)@0.2<PF<0.8 |
| Reactive Electrical Energy, Inductive or Capacitive | 0.000Varh-9000.0MVarh / 0.001Varh / ±(1%+3dgt)@PF<-0.5 0.000Varh-9000.0MVarh / 0.001Varh / ±(1.5%+10dgt)@-0.5<PF<-0.2 |
| Apparent Electrical Energy | 0.000VAh-9000.0MVAh / 0.001VAh / ±(1%+3dgt) |
| Phase Angle | -179°~180° / 1° / ±2° |
| Tanφ (VA≥50VA) | -32.76~32.76 / 0.001 / φ:±1° |
| DPF | -1.000~1.000 / 0.001 / φ:±1° |
| Harmonic Ratio 1~50 (Vrms>50V) |
0.0%~99.9% / 0.1% / ±(1%+5dgt) |
| Harmonic Angle (Vrms>50V) |
-179°~180° / 1° / ±3°@1-25th -179°~180° / 1° / ±10°@26-50th |
| Total Harmonic Ratio (THD or THDF)≤50 |
0.0%~99.9% / 0.1% / ±(1%+5dgt) |
| Distortion Factor (DF or THD-R)≤50 |
0.0%~99.9% / 0.1% / ±(1%+10dgt) |
| Transformer K Factor | 1.00~99.99 / 0.01 / ±5% |
| 3 Phase Unbalance | 0.0%~100% / 0.1% / ±1% |
| CT Turn Ratio | √ |
| Expert mode | √ |
| Harmonic | 1-50th |
| Total Harmonic distortion | √ Per phase |
| Number of Transient Record | 150 groups |
| Voltage Flicker | √ |
| Motor Starting Current detect | 100S |
| Three Phase Unbalance | √ |
| Record | 960 days @1 second interval, 20 parameters each time |
| Min/Max | √ |
| Alarm | 12800 groups of alarm records, 40 kinds of parameters are optional |
| Peak Value | √ |
| Screenshot Capacity | 60 |
| Comm port | USB |
| Withstand Voltage | 1min @ 3700Vac/50Hz,Case to line |
| Insulation | 10MΩ |
| Safety Regulation | IEC-61010,CATIII 1000V/IEC61010-31/IEC61326 |
| Display Mode | 640*480, 5.6inch, 116x88mm |
| Device Mode | 265x215x85mm |
| Instrument Weight | 1.6kgs(with battery), power adapter0.9kgs,Packing size with protective box and transformer, <15KGS |
| Power | 9.6V lithium battery |
| Power Consumption | Fully charged for 8 hours |
| Memory | Built-in 2G memory card |
| Waveform real-time display | 4 voltages/4 currents |