Features
- Output frequency 1.0-120Hz
- Adjustable V/f curve
- Carrier frequency up to 10 kHz
- Auto torque boost
- Build-in MODBUS communication, baud rate up to 9600 bps
- Built-in EMI filter
Application
- Machine tools
- Textile machines
- Woodworking machines
- Packaging machines
- Electronics
- Fans
- Pumps
- Air compressors
Specification
Voltage Class | 115V | 230V | |||||||
Model Number VFD-_ _ _L_ _ | 002 | 004 | 002 | 004 | 007 | 015 | 022 | ||
Applicable Motor Output (kW) | 0.2 | 0.4 | 0.2 | 0.4 | 0.7 | 1.5 | 2.2 | ||
Output Rating | Rated Output
Capacity (KVA) |
0.6 | 1.0 | 0.6 | 1.0 | 1.6 | 2.7 | 4.2 | |
Rated Output Current (A) | 1.6 | 2.5 | 1.6 | 2.5 | 4.2 | 7.0 | 11.0 | ||
Max. Output Voltage (V) |
3-phase corresponds to double
input voltage |
Three-phase corresponds to input voltage |
|||||||
Rated Frequency (Hz) | 1.0~400Hz | ||||||||
Power | Rated Input Current (A) | 6 | 9 | 4.9/1.9 | 6.5/2.7 | 9.7/5.1 | 15.7/9 | 24 | |
Input voltage Tolerance |
Single phase 90~132V
50/60Hz |
Single / 3-phase 180~264V 50/60Hz |
Single phase 180~264V
50/60Hz |
||||||
Frequency tolerance | ±5% | ||||||||
Control Characteristics | Control system | SVPWM (Sinusoidal Pulse Width Modulation, carried frequency 3kHz~10kHz) | |||||||
Output Frequency Resolution | 0.1Hz | ||||||||
Torque Characteristics | Including the auto-torque, auto-slip compensation, starting torque can be 150% at 5 Hz | ||||||||
Overload Endurance | 150% of rated current for 1 minute | ||||||||
Accel/Decel Time | 0.1~600Sec. (can be set individually) | ||||||||
V/F pattern | V/F pattern adjustable | ||||||||
Stall Prevention Level | 20~200%, setting of Rated Current | ||||||||
Operating Characteristics |
Frequency Setting |
Keypad | Setting by ▲▼ keys or V.R | ||||||
External Signal | Potentiometer-5KÙ/0.5W, DC 0 ~ +10V (input impedance 47KÙ),
4~20mA (output impedance 250Ù), multi-function inputs1 to 3 (3steps, JOG, UP/DOWN command), communication setting |
||||||||
Operation
Setting |
Keypad | Setting by RUN//STOP keys | |||||||
Signal | External
Signal |
M0,M1,M2,M3 can be combined to offer various modes of operation,
RS-485 communication port |
|||||||
Multi-function Input Signal | Multi-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/decel switch, counter, PLC Operation, external Base Block
(NC,NO) selection |
||||||||
Multi-function Output Signal | AC Drive Operating, Frequency Attained, Non-zero speed, Base Block, Fault Indication, Local/Remote indication, PLC Operation
indication. |
||||||||
Other Function |
AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency Setting of DC Braking , Over-Current Stall Prevention, Momentary Power
Loss restart, Reverse Inhibition, Frequency Limits, Parameter Lock/Reset |
||||||||
Protection | Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing | ||||||||
Other | Including EMI Filter | Without
EMI Filter |
|||||||
Cooling | Forced air-cooling | ||||||||
Environment | Installation Location | Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust | |||||||
Ambient Temperature | -10℃-40℃ (Non-Condensing and not frozen) | ||||||||
Storage Temperature | -20℃ to 60℃ | ||||||||
Ambient Humidity | Below 90%RH (non-condensing) | ||||||||
Vibration | 9.80665m/s2(1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz |