WDR-120 series 120W Single Output Industrial DIN RAIL

Contact us

Feature

  • Single and two phase wide input range 180 ~ 550VAC
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL508(industrial control equipment}approved
  • BS EN/EN61000-6-2(BS EN/EN50082-2} industrial immunity level
  • 100% full load burn-in test
  • Built-in DC OK relay contact
  • 3 years warranty

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

 

MODEL WDR-120-12 WDR-120-24 WDR-120-48
 

 

 

 

 

 

OUTPUT

DC VOLTAGE 12V 24V 48V
RATED CURRENT 10A 5A 2.5A
CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~2.5A
RATED POWER 120W 120W 120W
RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 12 ~ 15V 24 ~ 29V 48 ~ 58V
VOLTAGE TOLERANCE Note.3 ±1.5% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE, HOLD UP TIME 2000ms, 70ms, 50ms/400VAC           2000ms, 70ms, 10ms/230VAC at full load
 

 

 

 

INPUT

VOLTAGE RANGE 180 ~ 550VAC           254 ~ 780VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 89.5% / 400V 91% / 400V 92% / 400V
AC CURRENT 0.7A/400VAC           1.2A/230VAC
INRUSH CURRENT (max.) COLD START 50A
LEAKAGE CURRENT <3.5mA / 530VAC
 

 

 

PROTECTION

 

OVERLOAD

105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
 

OVER VOLTAGE

16 ~ 18V 31 ~ 37V 60 ~ 67V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK SIGNAL Relay contact rating(max.) : 30V / 1A resistive
 

 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
 

 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL508, EAC TP TC 004 , BIS IS13252(Part1)(only for 12V,24V) approved, IEC62368-1 CB approved by SIQ; Design refer to BS EN/EN62368-1, AS/NZS 62368.1(meet BS EN/EN60204-1)
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61204-3, BS EN/EN61000-6-2 (BS EN/EN50082-2),

heavy industry level, EAC TP TC 020

 

OTHERS

MTBF 1509.6K hrs min.       Telcordia SR-332 (Bellcore) ; 268.1K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 40*125.2*113.5mm (W*H*D)
PACKING 0.65Kg; 20pcs/14Kg/1.16CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quick may lead to increase of the set up time.

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.