TH11 Modular Endress Hauser Temperature Transmitter

The TH11 Modular Endress Hauser Temperature Transmitter is RTD designed for use in the process industry or factory automation type of environment. They are made up of a measurement probe with an RTD, insulation, and sheath.

Contact us

Features

  • High flexibility due to modular assembly with standard terminal heads and customized immersion length
  • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!
  • Improved galvanic isolation on most devices (2 kV)
  • Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solution.
  • All iTEMP® transmitters provide long term stability ≤ 0.05 % per year
  • Fast response time with reduced/tapered tip form
  • Head or field transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™

 

Specification

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    US style
    modular temperature assembly
    threaded process connection
    direct immersion style

  • Thermowell / protection tube

    without (not intended to be used with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible
    PTFE-insulated, rigid

  • Outer diameter protection tube / Insert

    1/8” (3,18 mm)
    3/16”(4,76 mm)
    1/4” (6,35 mm)
    3/8” (9,53 mm)

  • Max. immersion length on request

    up to 96″ (2439 mm)
    others on request

  • Material protection tube/ thermowell

    Sensor sheath
    316/316L

  • Process connection

    male thread:
    G1/2″
    NPT1/2″
    compression fitting:
    NPT1/8″
    NPT1/4″

  • Tip shape

    straight
    reduced

  • Surface roughness Ra

    Not Defined

  • Operating temperature range

    PT 100:
    -200 °C …600 °C
    (-328 °F …1.112 °F)

  • Max. process pressure (static)

    at 20°C: 250 bar (3.626 psi)
    depends on configuration

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751

  • Response time

    63% rt = 2,0 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex – approvals

    transmitter only
    FM IS
    CSA IS
    FM/CSA IS

  • Certification

    SIL (transmitter only)