Usage of Device and Working Principle:
Please connect the device according to the diagram.
Please define the function and time settings before energising the device.
Time=Maximum time(tm) x Time Scale Factor (Xn)
Example: Lets say If the device is energised, it is desired that the relay becomes activated for 15 mins. and then should not be
deactivated until de-energised.
Adjust the fn button to 2.Then adjust the MAX button ™ to 30 min [g] and the time scale factor button to 30m.[ 15 min= [30
min]x0.5] After the desired function and time is adjusted, the device can be energised accordingly.
Function Button(Fn)
-1- ON Delay
After the device is powered on, the delay starts, the M Led flashes during timing, and the relay is output after the delay ends,
relay Led is on and the M Led is on.
Re-execution requires power-off reset.
Technical Parameters:
Type | AERX-10 |
Operating Voltage(Un) | 150-260VAC(A1-A2),24VAC/DC(A2-A3) |
Operating Frequency | 50/60Hz |
Operating Power | <4VA |
Ambient Conditions;Humidity
|
-20℃…+55℃ |
Time | 1 sec.-30 hours |
Display |
Relay.T switch(S).status(M)and power(On)leds
|
Connection type | Terminal connection |
Weight | 68g |
Contact | 5A/250VAC(Rosistive load) |
Mounting | Assembled on the din rai |
Protection Class | IP20 |
Operating Altitude | <2000meter |
Cable Diameter | 2.5mm².1.5mm |