Features of 3730-3 Electropneumatic Positioner
- Electropneumatic positioner with HART® communication
- SAM DIGITAL READY
- Die-cast aluminum or stainless steel housing
- Attachment to linear actuators according to IEC 60534-6, VDI/VDE 3847, or SAMSON integral attachment
- Attachment to rotary actuators according to VDI/VDE 3845
- Attachment to double-acting actuators with Type 3710 Reversing Amplifier
- Integrated EXPERTplus diagnostics for control valves
- Any desired mounting position of the positioner (but not suspended)
- Simple one-knob, menu-driven operation
- Easy-to-read display in any mounting position thanks to rotatable reading direction
- Configurable with a computer over the SSP interface using the TROVIS-VIEW software
- Variable automatic start-up thanks to four different initialization modes
- Preset parameters, only values deviating from the standard need to be adjusted
- Calibrated travel sensor without gears susceptible to wear
Specifications of 3730-3 Electropneumatic positioner
-
-
Type 3730-3 Positioner The technical data for the explosion-protected devices may be restricted by the limits specified in the test certificates. Valve travel Adjustable Direct attachment to Type 3277 Actuator Attachment according to IEC 60534-6 (NAMUR) Attachment according to VDI/VDE 3847 Attachment to rotary actuators (VDI/VDE 3845)
3.6 to 30 mm 3.6 to 300 mm
3.6 to 300 mm
24 to 100° opening angle
Travel range Adjustable Adjustable within the initialized travel/angle of rotation of the valve; travel can be restricted to 1/5 at the maximum.
Set point w
Signal range 4 to 20 mA · Two-wire device, reverse polarity protection Minimum span 4 mA Static destruction limit 100 mA Minimum current 3.6 mA for display · 3.8 mA for operation Load impedance ≤ 8.2 V (corresponds to 410 Ω at 20 mA) Supply air
Supply pressure 1.4 to 7 bar (20 to 105 psi) Air quality acc. to ISO 8573-1
Max. particle size and density: Class 4 · Oil content: Class 3 · Pressure dew point: Class 3 or at least 10 K below the lowest ambient temperature to be expected
Signal pressure (output) 0 bar up to the capacity of the supply pressure · Can be limited to 1.4 bar/2.4 bar/3.7 bar ± 0.2 bar by software
Characteristic
Adjustable
Linear/equal percentage/reverse equal percentage User-defined (over operating software and communication)
Butterfly valve, rotary plug valve and segmented ball valve: linear/equal percentage
Deviation ≤1 % Hysteresis ≤0.3 % Sensitivity ≤0.1 % Transit time Venting or filling with air adjustable separately up to 240 s by software Direction of action Reversible Air consumption, steady state Independent of supply air approx. 110 ln/h Air output ca- pacity to fill actuator with air At Δp = 6 bar: 8.5 mn³/h · At Δp = 1.4 bar: 3.0 mn³/h · KVmax (20 °C) = 0.09 to vent actuator At Δp = 6 bar: 14.0 mn³/h · At Δp = 1.4 bar: 4.5 mn³/h · KVmax(20 °C) = 0.15 Permissible ambient temperature
–20 to +80 °C (all versions) –45 to +80 °C with metal cable gland
–55 to +80 °C Special version for low temperatures with metal cable gland (on request)
The temperature limits for the explosion-protected devices may be further restricted by the limits spe– cified in the test certificates.
Influences
Temperature ≤0.15 %/10 K Supply air None Effect of vibration ≤0.25 % up to 2000 Hz and 4 g according to IEC 770 Electromagnetic compatibility Complying with EN 61000-6-2, EN 61000-6-3, EN 61326-1 and NAMUR Recommendation NE 21 Electrical connections
One M20x1.5 cable gland for 6 to 12 mm clamping range Second M20x1.5 threaded connection additionally available Screw terminals for 0.2 to 2.5 mm² wire cross-section Degree of protection IP 66/NEMA 4X Use in safety-instrumented systems (SIL) Emergency venting at 0 mA set point
and using optional solenoid valve
Observing the requirements of IEC 61508, the systematic capability of the pilot valve for emergency venting as a component in safety-instrumented systems is given.
Use is possible on observing the requirements of IEC 61511 and the required hardware fault tolerance in safety-instrumented systems up to SIL 2 (single device/HFT = 0) and SIL 3 (redundant configuration/ HFT = 1). Explosion protection See Table 3 Communication (local) SAMSON SSP interface and serial interface adapter Software requirements (SSP) TROVIS-VIEW with database module 3730-3 Communication (HART®) HART® field communication protocol Impedance in HART® frequency range: Receiving 350 to 450 Ω · Sending approx. 115 Ω
Software re- quirements (HART®) For handheld communi- cator
Device description for Type 3730-3
For PC
DTM file according to specification 1.2, suitable for integrating the device into frame applications that support the use of FDT/DTM (e.g. PACTware); other integrations (e.g. AMS, PDM) available Compliance ·
-