Usage and Working Principle
Display: Displayed here while setting the time and counting down the set time. If the operating time is set in minutes, the
rightmost point of the display flashes while the device is counting the time. t Knob: To set the working time value, move the knob
to the desired value. When setting the time, the set time is displayed on the screen. (If the time is changed while the device is
counting time, the device continues to count the new time set.) x Knob: To set the time range, move the“x” knob to the desired
value. The right side is reserved x Knob: To set the time range move the“x” knob to the desired value.9.9 sec., 99 sec., 9.9 min.,
99 min., 9.9 hours., 99 hours 6 different periods can be set. When the time range is set while the device is powered, the
The device must be de-energized and re-energized for the adjusted time range to be valid.
Maintenance
Switch off the device and release from connections. Clean the trunk of the device with a swab. Don’t use any conductor or chemical
might damage the device. Make sure the device works after cleaning
Warnings
Please use the device according to the manual. Don’t use the device in wet. Include a switch and circuit breaker in the assembly.
Put the switch and circuit breaker near the device, and the operator can reach it easily. Mark the switch and circuit breaker as releasing a connection for the device.
Technical Parameters:
Type | ADRV-08 | ADRV-10 |
Operating Voltage | 150V-260VAC 24V DC,or110VAC 24V DC | 110Vor230VAC(A1-A2)or24VAC/DC(A2-A3 |
Function | ON Delay ON Delay or OFF Delay | |
Operating Frequency | 50/60Hz | |
Operating Power | <4VA | <6VA |
Ambient Conditions;Humidity
|
20……+55℃ | |
Time |
9.9(sec),99(sec),9.9(min)
99(min),9.9(hr),99(hours)
|
0.1(sec)~99(min) |
Display |
01×2 digit,on led and out(RLY )led
|
|
Output contact | 5A/250VAC (Resistive Load) | |
Mounting | Assembld on the din rail | |
Operating Altitude | c2000mete | |
Weigh | 79g | |
Cable Diameter | 2.5mm |
Installation dimensions and wiring requirements