AQ-M255 MOTOR PROTECTION DEVICE

The AQ-M255 motor protection device offers a modular protection and control solution for larger and more important motors that require a large I/O capacity. You can add up to eleven (11) I/O or communication cards into the device for extensive monitoring and control applications. You can also connect up to sixteen (16) RTD signals for thermal alarming and tripping. AQ-M255 communicates using various protocols, including the IEC 61850 substation communication standard.

Contact us
Category:

Feature of AQ-M255 MOTOR PROTECTION DEVICE

  • Powerful motor management with a large I/O capacity.
  • Five (5) thermal models (time constant accurate).
  • Soft start protection beginning from 6 Hz.
  • Wye-delta started motor supervision.
  • Two-speed motor protection.
  • Optional power and energy measurement accuracy of up to 0.2 %.
  • Asynchronous and synchronous motors.

 

Specification of AQ-M255 MOTOR PROTECTION DEVICE

Overcurrent Protection Non-Directional Overcurrent: I> (50/51) – 4 stages (INST, DT, or IDMT)
Non-Directional Earth Fault: I0> (50N/51N) – 4 stages (INST, DT, or IDMT)
Directional Overcurrent: Idir> (67) – 4 stages (INST, DT or IDMT)
Directional Earth Fault: I0dir> (67N/32N) – 4 stages (INST, DT or IDMT)
Negative Sequence Overcurrent/Phase Current Reversal/Current Unbalance: I2> (46/46R/46L) – 4 stages (INST, DT or IDMT)
Harmonic Overcurrent: Ih> (50H/51H/68H) – 4 stages (INST, DT, or IDMT)
Circuit Breaker Failure Protection (CBFP): 50BF/52BF
High-Impedance or Low-Impedance Restricted Earth Fault/Cable End Differential: I0d> (87N)
Voltage Protection Overvoltage: U> (59) – 4 stages (INST, DT or IDMT)
Undervoltage: U< (27) – 4 stages (INST, DT or IDMT)
Neutral Overvoltage: U0> (59N) – 4 stages (INST, DT or IDMT)
Sequence Voltage: U1/U2>/< (47/27P/59PN) – 4 stages (INST, DT or IDMT)
Frequency Protection Over Frequency and Under Frequency: f>/< (81O/81U) – 8 stages (INST or DT)
Rate-of-Change of Frequency: df/dt>/< (81R) – 1 stage (DT)
Power Protection P, Q, S>/< (32) – 4 stages (DT)
Motor Protection Machine Thermal Overload: TM> (49M)
Motor Status Monitoring
Motor Start/Locked Rotor Monitoring: Ist> (48/14)
Frequent Start: N> (66)
Non-Directional Undercurrent: I< (37)
Mechanical Jam: Im> (51M)
Power Factor Protection: PF< (55)
Additional Protection: Voltage Memory
Programmable Stage: PGx>/< (99)
Arc Protection (Optional): IArc>/I0Arc> (50Arc/50NArc)
Control Number of objects to control and monitor: 10
Number of indicators to monitor: 10
Number of setting groups: 8
Measuring and Monitoring Phase, sequence and residual currents (IL1, IL2, IL3, I01, I02)
Phase, sequence and residual voltages (UL1, UL2, UL3, U12, U23, U31, U0)
Frequency (f)
Power (P, Q, S, pf) and Energy (E+, E-, Eq+, Eq-)
Power and energy class 0.5
Power and energy measurement accuracy of up to 0.2 % (optional)
Current transformer supervision
Voltage transformer supervision (60)
Circuit breaker wear monitoring
Total harmonic distortion (current)
Total harmonic distortion (voltage)
Running hour counter
Measurement recorder
Measurement value recorder
Event recorder (max. 15 000 permanent event records)
Disturbance recorder (max. 100 records á 5 seconds at 3.2 kHz sampling)
Hardware Current inputs: 5
Voltage inputs: 4
Digital inputs (fixed): 3
Digital outputs (fixed): 5
Number of empty slots: 11
Digital inputs: +8/16/24/32/40/48/56/64/72/80/88 (optional)
Digital outputs: +5/10/15/20/25/30 (optional)
Milliampere I/O module (4 mA outputs + 1 mA input)
Arc protection module (4 sensors + 2 HSO + 1 BI)
Communication media (see “Communication” below)
External I/O modules (see “Accessories” below)
Communication Input RJ-45 100 Mbps Ethernet (front panel, fixed)
RJ-45 100 Mbps Ethernet and RS-485 (rear panel, fixed)
2 x RJ-45 100 Mbps Ethernet with an IRIG-B input (optional)
2 x ST 100 Mbps Ethernet with an IRIG-B input (optional)
2 x LC 100 Mbps Ethernet (PRP/HSR) (optional)
RS-232 serial fiber (PP/PG/GP/GG) (optional)
Communication Protocols IEC 61850 (edition 1)
IEC 61850 (edition 2)
IEC 60870-5-101/104
IEC 60870-5-103
Modbus/RTU and Modbus/TCP
DNP3
SPA

 

AQ-M255 MOTOR PROTECTION DEVICE Application

Application Drawing of AQ-M255 motor protection device