H3CR-H Power OFF Delay Timer DIN 48 × 48-mm

This power off delay timer is produced by Ormon.

Contact us
Category:

Feature

• Long power OFF-delay times;

  • S-series: up to 12 seconds,
  • M-series: up to 12 minutes.

• Models with forced-reset input are available.

• 11-pin and 8-pin models are available.

Specifications

 

Item H3CR-H8L H3CR-H8RL H3CR-HRL
Operating/Reset method Instantaneous operation/
Time-limit reset
Instantaneous operation/Time-limit reset/Forced reset
Pin type 8-pin 11-pin
Input type No-voltage input
Output type Relay output (DPDT) Relay output (SPDT) Relay output (DPDT)
Mounting method DIN track mounting, surface mounting, and flush mounting
Approved standards UL508, CSA C22.2 No.14, NK, Lloyds, CCC: GB/T 14048.5 *
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.

 

Note: For details, refer to your OMRON website.
* CCC certification requirements

 

Recommended fuse 0216005 (250VAC, 5A), manufactured by Littelfuse
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Rated insulation voltage 250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.)
4 kV (at 240 VAC)
Conditional short-circuit current 1000 A

 

Time Ranges

 

Time unit S-series M-series
Scale number (max.) s (sec) min (min)
0.6 Set time range 0.05 to 0.6
1.2 0.12 to 1.2
6 0.6 to 6
12 1.2 to 12
Min. power ON time 0.1 s min. 2 s min.
Time-up operation repeat period 3 s min.
Forced-reset repeat period 3 s min.

 

 

Note: 1. If the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above
minimum power ON time.
2. Do not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or
burning. Refer to Safety Precautions (H3CR-H) on Catalog for details.