ATEC MDM3100 Multifunction Power Meter

ATEC MDM3100 is a powerful Multifunction Power Meter that measures more than 60 parameters such as U I P, Q, cos, F, kWh, kvarh, etc. The standard MDM3100 has RS-485 communication protocol, and 2 energy pulse outputs( active and reactive each) functions. With an optional module, MDM3100 can perform more functions: harmonic analysis, 8 digital signal inputs, 4 programmable relay outputs, 4 programmable analog outputs (0-5V or 4-20mA), data storage, Profibus communication, and Ethernet networking capabilities. MDM3100 fulfills all the important requirements of IEC60668; IEC61557-12; IEC61000-4-30 and CE standards as LVD EN61010; EMC EN62052-11 and EN62053-21.

Contact us

Features of ATEC MDM3100

  • LCD
  • Measure over 60 parameters.
  • RS-485 port, Modbus RTU communication protocol
  • Dual-energy pulse output
  • Harmonic analysis (optional), up to 63th
  • 8 channels of digital remote signals ˆ
  • 4 channels programmable analog output ‰
  • 4 channels relay output
  • Profibus communication (optional)
  • Ethernet networking communication(optional)
  • Data memory(optional)

Specifications of ATEC MDM3100

Current Input
Input Current:0~5A   (Current value can be set up)

Measurement scope:0.5%~120%In

Overload capacity:2 X rated continuously,100A/1s non continuously

Power consumption:≤0.2VA per phase

Voltage Input
Input Voltage:0~400VAC (L-N),0~693VAC(L-L)(Voltage value can be set up)

System frequency:45~65Hz

Measurement scope:3%~120%Un

Overload Capacity:2 X rated continuous, 2500V/1s non continuous

Power consumption:≤0.5VA per phase

Switch Status (optional)
Input Channels:

Input Type:

Isolated Voltage:

8 channels

Dry contact

2500VAC

Relay Output (optional)
Output Channels 4 channels programmable
Output Type Mechanic contact, constant on output
Contact Capacity 5A/250VAC
Analog Output (optional)
No. of outputs 4 channels programmable
Output signal 4~20mA or 0~5V
Response time ≤400ms
Pulse Output (standard)
No. of outputs 2 channels(active/reactive energy each)
Serial com. Port (standard)
No. of outputs 1 RS-485 port
Communication protocol Modbus-RTU protocol
Baud rate 2400,4800,9600,19200,38400 bps
Profibus com. Module (optional)
No. of Channels 1channel
Communication protocol Profibus-DP  protocol
Ethernet networking Module (optional)
No. of outputs 1 channel 10M/100M adaptive
Communication protocol TCP/IP  protocol
Other parameters
Auxiliary Power 85~265VAC/DC
Display module LCD display luminosity can be adjusted
Temp. drifting factor

Withstand Voltage(input against output )

Total power consumption

Operation temperature

Storage temperature

Operation humidity

Pollution Class

Material of housing

<100PPM/℃

2500V/1min

<8VA

-20℃~60℃

-40℃~85℃

5~95%RH

2 Class

Flammability acc.  To UL94V0

Main unit 96 x 96 x 86mm
Dimensional Size: Main unit+ module 96 x 96 x 122mm
Installation Size: 91 x 91mm