Feature
- Stepless control of air pressure in proportion to electrical signals
- Sensitivity: 0.2 kPa (100 kPa specification)
- Linearity: ±1% or less (F.S.)
- Hysteresis: 0.5% or less (F.S.)
- Communication: CC-Link, DeviceNet™, PROFIBUS DP, RS-232C, IO-Link
Specification
| Mode | NITVX2000 | |
| Minimum supply pressure | Whichever is higher: 0.5 MPa or the set pressure +0.2 MPa | |
| Maximum supply pressure | 5MPa Note2) | |
| Set pressure range Note 3 ) | 0.01 to 3.0 MPa | |
| Power supply | Voltage | 24 VDC ±10% |
| Current consumption | 0.12 A or less | |
| Input signal | Current type Note 4 ) | 4 to 20 mA DC, 0 to 20 mA DC (Sink type) |
| Voltage type | 0 to 5 VDC, 0 to 10 VDC | |
| Input impedance | Current type | 500Ω or less |
| Voltage type | 6~6.5KΩ(at ordinary temperature) | |
|
Output signal Note 5 ) (Monitor output) |
Analog output |
1 to 5 VDC (Output impedance: Approx. 1KΩ) Output accuracy: ±6% or less (Full span) |
| 4 to 20 mA DC (Sink type) Load impedance: 250 Ω or less Output accuracy: ±6% or less (Full span) | ||
|
Switch output |
NPN open collector output: Max. 30 V, 80 mA | |
| Hysteresis: ±3% (Full span), Self-diagnosis: ±5% or less (Full span) | ||
| PNP open collector output: Max. 80 mA | ||
| Hysteresis: ±3% (Full span), Self-diagnosis: ±5% or less (Full span) | ||
| Linearity | ±1% or less (Full span) | |
| Hysteresis | 1% or less (Full span) | |
| Repeatability | ±1% or less (Full span) | |
| Sensitivity | ±1% or less (Full span) | |
| Temperature characteristics | ±0.12% or less (Full span)/°C | |
| Output pressure display | Accuracy | ±2% or less (Full span) ±1 digit |
| Minimum unit N o t e 6 ) | MPa:0.01,kgf/cm2:0.1,bar:0.1,ps:1 | |
| Fluid | Air、N2、O2、Ar | |
| Ambient and fluid temperature | 0-50℃(No condensation) | |
| Weight | Approx. 570 g (without options) | |