RQ- 65 series 65W Quad Output Switching Power Supply

Contact us

Feature

  • Miniature size, non-PFC
  • 5G vibration, 70℃ operation
  • 300VAC input surge
  • Suitable for critical applications
  • 2 outputs are isolated for RID series

 

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

 

MODEL RQ-65B RQ-65C RQ-65D
 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V
RATED CURRENT 6A 2A 0.5A 0.5A 5A 2A 0.5A 0.5A 4A 1.5A 1A 0.5A
CURRENT RANGE          Note.6 0 ~ 8A 0 ~ 3A 0 ~ 1A 0 ~ 1A 0 ~ 8A 0 ~ 3A 0 ~ 1A 0 ~ 1A 0 ~ 8A 0 ~ 3A 0 ~ 1.5A 0 ~ 1A
RATED POWER         Note.6 62.5W 65W 68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% +9,-5% ±5.0% ±5.0% ±2.0% +10,-4% ±5.0% ±5.0% ±2.0% +6,-10% +6,-10% ±5.0%
LINE REGULATION Note.4 ±0.5% ±1.5% ±0.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±0.5% ±1.5% ±2.0% ±0.5%
LOAD REGULATION Note.5 ±0.5% ±3.0% ±1.0% ±1.0% ±0.5% ±4.0% ±1.0% ±1.0% ±0.5% ±3.0% ±5.0% ±1.0%
SETUP, RISE TIME 500ms, 20ms/230VAC  1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC  14ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 75% 75% 77%
AC CURRENT (Typ.) 2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

PROTECTION

OVERLOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020
 

OTHERS

MTBF 2466.8K hrs min.                                                                                         Telcordia SR-332 (Bellcore) ; 424.2K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION 129*98*38mm (L*W*H)
PACKING 0.44Kg; 30pcs/13.2Kg/0.72CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.

6. Each output can work within current range. But total output power can’t exceed rated output power.

7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).