The VigiPacT RH197P is a sophisticated residual current protection relay designed to safeguard your electrical system from various threats.

  • Electrical shocks: Protects people from both direct and indirect contact with hazardous currents.
  • Property fires: Helps prevent fires caused by electrical leakage.
  • Motor damage: Offers protection for motors in case of ground faults.
Contact us

The Schneider VigiPacT RH197P is an ideal solution for ensuring safety and reliability in your electrical system.

How does the Schneider Residual Current Monitoring System work?

  • Mounted on a front panel for easy access.
  • Measures leakage current through a separate toroid sensor (not included).
  • Trips the connected circuit breaker if the leakage current exceeds a user-defined threshold

 

Features of Schneider Residual Current Monitoring System

  • Wide range of sensitivity: Adjustable from 30 mA to 30 A for tailored protection.
  • Customizable time delay: Selectable between instant and 4.5 seconds to suit specific applications.
  • Type A earth leakage protection: Covers AC, pulsating DC, and mixed AC/DC residual currents.
  • Flexible reset options: Choose between manual or automatic reset after a fault.
  • High voltage monitoring: Up to 1000 VAC for a wider range of applications.
  • Durable construction: IP40 enclosure protects against dust and limited water ingress.
  • Schneider Electric compatibility: Requires a compatible Schneider Electric type A toroid or rectangular sensor (sold separately).

Specification of Schneider Residual Current Monitoring System

Main
Range VigiPacT
Device short name RH197P
product or component type Residual current protection relay
relay application Protection relay
mounting support Front panel
Earth-leakage protection class Type A
Type of setting Selector
Residual earth-leakage sensitity adjustment type Adjustable 19 settings
Earth-leakage sensitivity 0.03…30 A
Earth-leakage time delay Instantaneous for 0.03 A
Adjustable 7 settings 0…4.5 s for 0.03…30 A
Alarm threshold 100 %
Current sensors compatibility VigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
[Ithe] conventional enclosed thermal current 8 A
Minimum load 10 mA at 12 V
[Us] rated supply voltage 220…240 V AC 50/60 Hz 70…110 %
Power consumption in VA 4 VA
Monitored distribution system 1000 V – AC at 50/60 Hz (maximum)
1000 V – AC at 400 Hz (maximum)
Earthing system TT
IT
TN-S
[Uimp] rated impulse withstand voltage 8 kV
Reset Manual reset
Automatic reset