Feature
- High voltage output (115/230/380V)
- Fanless and conduction-cooled design
- Slim and 1U Low profile (41mm)
- Built-in active PFC function
- DC 12V/0.4A auxiliary power
- Output voltage and constant current level programmable(PV/PC)
- Protections: Short circuit / Over load /Over voltage / Over temperature
- Built-in remote ON-OFF control and DC OK signal
- Operating altitude up to 2000 meters (E type Note.6,
- Blank/PM/CAN type Note.7)
- LED indicator for power on
- Optional PMBus or CANBus protocol
- 5 years warranty
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment
- or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- DC centralized bus(Lighting)
Specification
MODEL | UHP-1500-380E | |||
OUTPUT |
DC VOLTAGE(DEFAULT) | 380V | ||
RATED CURRENT (Max.) | 3.95A | |||
RATED POWER (Max.)(Note.7) | 1501W | |||
RIPPLE & NOISE (Max.) Note.2 | 3800mVp-p | |||
VOLTAGE ADJ. RANGE | By built-in potentiometer, SVR | |||
350~420V | ||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | |||
LINE REGULATION | ±0.5% | |||
LOAD REGULATION | ±0.5% | |||
SETUP, RISE TIME | 1800ms, 60ms/230VAC at full load | |||
HOLD UP TIME (Typ.) | 16ms/230VAC at 75% load 10ms/230VAC at full load | |||
INPUT |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 250 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
POWER FACTOR (Typ.) | PF≥0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 95.5% | |||
AC CURRENT (Typ.) | 8A/230VAC | |||
INRUSH CURRENT (Typ.) | Cold start 60A/230VAC | |||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||
PROTECTION |
OVER LOAD | 105~125% rated output power | ||
Protection type : Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover. | ||||
SHORT CIRCUIT | Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover. | |||
OVER VOLTAGE | 428 ~ 460V | |||
Protection type :Shut down O/P voltage,re-power on to recover | ||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | |||
FUNCTION | REMOTE ON/OFF CONTROL | Power ON : Short circuit Power OFF : Open circuit | ||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note.6) |
SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||
WITHSTAND VOLTAGE Note 8 | OVC Ⅲ I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC | |||
ISOLATION RESISTANCE Note 8 | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||
EMC IMMUNITY |
BS EN/EN61000-6-2 | |||
Parameter | Standard | Test Level / Note | ||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||
OTHERS |
MTBF | 597.3K hrs min. Telcordia SR-332 (Bellcore) ; 63.3K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 290*140*41mm (L*W*H) | |||
PACKING | 2.51kg ; 6pcs/16.06kg/0.91CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance :includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. Refer to derating curve.
|