Meanwell UHP1500 HV series 1500W Conduction Cooling with High Voltage Output

Contact us

Feature

  • High voltage output (115/230/380V)
  • Fanless and conduction-cooled design
  • Slim and 1U Low profile (41mm)
  • Built-in active PFC function
  • DC 12V/0.4A auxiliary power
  • Output voltage and constant current level programmable(PV/PC)
  • Protections: Short circuit / Over load /Over voltage / Over temperature
  • Built-in remote ON-OFF control and DC OK signal
  • Operating altitude up to 2000 meters (E type Note.6,
  • Blank/PM/CAN type Note.7)
  • LED indicator for power on
  • Optional PMBus or CANBus protocol
  • 5 years warranty

 

Application

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment
  • or apparatus
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • DC centralized bus(Lighting)

Specification

MODEL UHP-1500-380E
 

 

 

 

OUTPUT

DC VOLTAGE(DEFAULT) 380V
RATED CURRENT (Max.) 3.95A
RATED POWER (Max.)(Note.7) 1501W
RIPPLE & NOISE (Max.) Note.2 3800mVp-p
VOLTAGE ADJ. RANGE By built-in potentiometer, SVR
350~420V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±0.5%
SETUP, RISE TIME 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC at 75% load      10ms/230VAC at full load
 

 

 

INPUT

VOLTAGE RANGE                                                Note.4 90 ~ 264VAC           250 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.95/230VAC at full load
EFFICIENCY (Typ.) 95.5%
AC CURRENT (Typ.) 8A/230VAC
INRUSH CURRENT (Typ.) Cold start 60A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
 

 

PROTECTION

OVER LOAD 105~125% rated output power
Protection type : Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover.
SHORT CIRCUIT Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover.
OVER VOLTAGE 428 ~ 460V
Protection type :Shut down O/P voltage,re-power on to recover
OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION REMOTE ON/OFF CONTROL Power ON :  Short circuit          Power OFF : Open circuit
 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
 

 

 

 

 

 

SAFETY & EMC

(Note.6)

SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE Note 8 OVC Ⅲ I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC
ISOLATION RESISTANCE Note 8 I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
 

 

EMC EMISSION

Parameter Standard Test Level / Note
Conducted BS EN/EN55032 (CISPR32) Class B
Radiated BS EN/EN55032 (CISPR32) Class A
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 —–
 

 

 

 

EMC IMMUNITY

BS EN/EN61000-6-2
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 3
EFT / Burst BS EN/EN61000-4-4 Level 3
Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

 

OTHERS

MTBF 597.3K hrs min.       Telcordia SR-332 (Bellcore) ; 63.3K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 290*140*41mm (L*W*H)
PACKING 2.51kg ; 6pcs/16.06kg/0.91CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance :includes set up tolerance, line regulation and load regulation.

4.  Derating may be needed under low input voltages. Please check the derating curve for more details.

5.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on     a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

6.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

7.  Refer to derating curve.