Feature of Incremental rotary encoder RHI90N
- Solid shaft
- SSI interface
- Up to 32 Bit multiturn
- Free-of-wear magnetic sampling
- High resolution and accuracy
- Additionally push buttons for preset function (only model characteristic SB2, SG2)
- Up to 4096 pulses on incremental track
Specifications of Incremental rotary encoder RHI90N
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute rotary encoder | |
Linearity error | ≤ ± 0.1 ° | |
UL File Number | E223176 “For use in NFPA 79 Applications only” , if UL marking is marked on the product. | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 55 E+8 revolutions at 40/110 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.5 … 30 V DC (SSI, SSI + RS422) ; 10 … 30 V DC (SSI + Push/Pull) | |
No-load supply current | typ. 50 mA | |
Power consumption | approx. 1.5 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI ; SSI + incremental track | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 … 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V … UB or unconnected (cw descending) | |
Low | 0 … 2 V (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V … UB | |
Low | 0 … 2 V | |
Input current | < 6 mA | |
Signal duration | min. 1.1 s | |
Output | ||
Output type | RS422, Push/Pull | |
Signal output | A+B+/A+/B | |
Pulses | 1024, 2048, 4096 | |
Connection | ||
Connector | M12 connector, 8-pin or M23 connector, 12-pin | |
Cable | ∅7 mm, 6 x 2 x 0.14 mm2, 1 m (cable length, see order code) | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 (not for M23 device plug) |
|
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 … 1000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source , if UL marking is marked on the product. | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 … 70 °C (23 … 158 °F), cable, fixed: -30 … 70 °C (-22 … 158 °F) connector models: -40 … 85 °C (-40 … 185 °F) |
|
Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
Relative humidity | 98 % , no moisture condensation |