Feature
- Controls air pressure in proportion to an electric signal
- Available in MPa, kgf/cm², bar, PSI, and kPa units
- Pressure range of -80kPa to 0.9MPa
- Available port sizes 1/4, 3/8 and 1/2
- Mounting bracket option
- Made-to-order options available for expanded features, including analog 4-20mA sourcing type, manifold mountable, high speed response, and others
Specification
Model | NITV001 | NITV003 | NITV005 | |
Minimum supply pressure | Set pressure+0.1MPa | |||
Maximum supply pressure | 0. 2MPa | 1. 0MPa | ||
Set pressure range | 0.001~0.1MPa | 0.001~0.5MPa | 0.001~0.9MPa | |
Voltage | 24 VDC ±10%, 12 to 15 VDC | |||
Power supply | Current consumption | Power supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less | ||
Input signal | Voltage type | DC0~5V. DC0~10V | ||
Current type | 4 to 20 mA DC, 0 to 20 mA DC (Sink type) | |||
Input impedance | Voltage type | Approx. 10 kΩ | ||
Current type | Approx. 250 Ω | |||
Output signalnote 4 ) | Analog output | 1 to 5 VDC (Output impedance: Approx. 1 kΩ) Output accuracy: ±6% F.S. or less | ||
Linearity | ±1% F.S. or less | |||
Hysteresis | 0.5% F.S. or less | |||
Repeatability | ±0.5% F.S. or less | |||
Sensitivity | 0.2% F.S. or less | |||
Temperature characteristics | ±0.12% F.S. /℃ or less | |||
Operating temperature range | 0 to 50°C (No condensation) | |||
Enclosure | Equivalent to Ip65※ | |||
Connection type | Built-in One-touch fittings | |||
Connection size |
For single unit | Metric size | 1 , 2 , 3 : 4 | |
Inch size | 1 , 2 , 3 : 5/32″ | |||
Manifold | Metric size | 1 , 3 : 6, 2 : 4 | ||
Inch size | 1 , 3 : 1/4″, 2 : 5/32″ | |||
Weightnote 1 ) | 100 g or less (without option) |