SICAM EFI Earth fault indicator for cables

Contact us

Feature

  • Dual power supply with AC/DC power supply and battery. Due to the battery, the device is self-sustaining and maintains its functionality even after the main power supply is tripped
  • Complies with IEC 61010-1 safety standard and IEC 62689-1 standard for short-circuit indicators
  • Easy setting via DIP switch
  • Configurable binary outputs, for remote messages to SCADA via RTU in the case of faults or for diagnostics
  • Local indication: 1 flag and 1 red LED for ground fault, 1 yellow LED for battery charge level, 1 green LED for AC/DC power supply
  • Several reset functions, auto reset (via time stages), remote reset via binary input or automatic reset on recovery of auxiliary voltage, net current or via AC/DC Binary inputs
  • Extended battery life with enhanced power management enabling more than 2,000 hours of operation under fault conditions (flashing)
  • Sensors with simple locking mechanism for perfect retrofitting to the MV cables
  • Sensor cable available with 3.5 m, 5 m or 16 m length
  • Built- in restraints to prevent fault detection due to inrush currents & auto reclosure operations using time muting logic

Specification

Medium-voltage cable distribution systems up to 36 kV (± 10%), 50 Hz/60 Hz

 

Signalization

 

Fault indication via LEDs

  • 1 flag red – earth fault
  • 1 LED red – earth fault
  • 1 LED yellow – battery charge level when push button is pressed
  • 1 LED green – auxiliary voltage available

 

Binary out- inputs

  • 1 binary output for external signal lamp earth fault
  • 1 binary output earth fault
  • 1 binary output battery monitoring
  • 2 binary inputs: 1x AC reset-input, 1x DC reset-input
  • 1 binary input remote test / reset
Sensor details

10% accuracy each

  • Sensor type 1: earth fault current 25 A to 100 A
    for 3 core cable applications
    sensor diameter 150 mm
    sensor cable length 3.5 m, 5 m
  • Sensor type 2: earth fault current 25 A to 240 A
    for 3 core cable applications
    sensor diameter 140 mm
    sensor cable length 16 m
  • Sensor type 3: earth fault current 25 A to 240 A
    for 3 single core cable applications
    flexible sensor diameter 220 mm to 340 mm
    sensor cable length 16 m
  • Sensor type 4: earth fault current 25 A to 240 A
    for 3 core cable applications
    sensor diameter 120 mm
    sensor cable length 16 m
Auxiliary voltage
  • Battery for 2,000 hours flashing time, service life of 15 years min
  • 110 – 230 V AC (± 20%)
  • 9 – 38 V DC

Temperature range

  • From -30°C to +75°C

Housing

  • Polycarbonate housing for surface mounting,
    optional L-clamp for panel mounting arrangement
  • Dimensions: 140 x 150 x 41 mm (W / H / D)
  • Protection class: SICAM EFI IP65W, sensor IP68W
  • Suitable for detached surface mounting