AQ-M210 Electric Motor Protection Devices

The AQ-M210 electric motor protection devices offer a modular protection and control solution for small and medium-sized motors. You can add up to four (4) I/O or communication cards into the device for more comprehensive monitoring and control applications. You can also connect up to twelve (12) RTD signals for thermal alarming and tripping. AQ-M210 communicates using various protocols, including the IEC 61850 substation communication standard.

Contact us
Category:

Feature of AQ-M210 electric motor protection devices

  • Five (5) thermal models (time constant accurate).
  • Soft start protection begins from 6 Hz.
  • Wye-delta started motor supervision.
  • Two-speed motor protection.

 

Specification of AQ-M210 electric motor protection devices

Protection Non-directional overcurrent (I>; 50/51) – 4 stages (INST, DT or IDMT)
Non-directional earth fault (I0>; 50N/51N) – 4 stages (INST, DT or IDMT)
Negative sequence overcurrent/ Phase current reversal/ Current unbalance (I2>; 46/46R/46L) – 4 stages (INST, DT or IDMT)
Harmonic overcurrent (Ih>; 50H/51H/68H) – 4 stages (INST, DT or IDMT)
Circuit breaker failure protection (CBFP; 50BF/52BF)
High-impedance or low-impedance restricted earth fault/ Cable end differential (I0d>; 87N)
Resistance temperature detectors (RTD)
Machine thermal overload (TM>; 49M)
Motor status monitoring
Motor start/ Locked rotor monitoring (Ist>; 48/14)
Frequent start (N>; 66)
Non-directional undercurrent (I<; 37)
Mechanical jam (Im>; 51M)
Programmable stage (PGx>/<; 99)
Arc protection (IArc>/I0Arc>; 50Arc/50NArc) (optional)
Control Number of objects to control and monitor: 5
Number of indicators to monitor: 5
Number of setting groups: 8
Cold load pick-up
Measuring and Monitoring Phase, sequence and residual currents (IL1, IL2, IL3, I01, I02)
Current transformer supervision
Circuit breaker wear monitoring
Total harmonic distortion (current)
Running hour counter
Measurement recorder
Measurement value recorder
Event recorder (max. 15 000 permanent event records)
Disturbance recorder (max. 100 records á 5 seconds at 3.2 kHz sampling)
Hardware Current inputs: 5
Digital inputs (fixed): 3
Digital outputs (fixed): 5
Number of empty slots: 4
Digital inputs: +8/16/24/32 (optional)
Digital outputs: +5/10 (optional)
Milliampere I/O module (4 mA outputs + 1 mA input)
Arc protection module (4 sensors + 2 HSO + 1 BI)
Communication media (see “Communication” below)
External I/O modules (see “Accessories” below)
Communication Input RJ-45 100 Mbps Ethernet (front panel, fixed)
RJ-45 100 Mbps Ethernet and RS-485 (rear panel, fixed)
2 x RJ-45 100 Mbps Ethernet with an IRIG-B input (optional)
2 x ST 100 Mbps Ethernet with an IRIG-B input (optional)
2 x LC 100 Mbps Ethernet (PRP/HSR) (optional)
RS-232 serial fiber (PP/PG/GP/GG) (optional)
Communication Protocols IEC 61850 (edition 1)
IEC 60870-5-101/104
IEC 60870-5-103
Modbus/RTU and Modbus/TCP
DNP3
SPA